Attribute
Description
Manufacturer Part Number
IP1201TR
Manufacturer
Description
IC REG BUCK ADJ SGL/DL 159BGA
Manufacturer Lead Time
26 weeks

Our team will assist you shortly.

Product Attributes

Type Description
Category
Import Duty Classification -
Product Series Line iPOWIR™
IC Encapsulation Type Tape & Reel (TR)
Availability Status Obsolete
Primary Function Mode Step-Down
Output Setup Options Positive
Circuit Topology Design Buck
Exit Signal Category Adjustable
Signal Output Quantity 1 or 2
Minimum Input Voltage 3.14V
Maximum Input Voltage 5.5V
Minimum Fixed Output 0.8V
Peak Output Voltage 3.3V
Output Delivery Amps 30A, 15A
Switching Cycle Rate 170kHz ~ 460kHz
Sync Rectification Mode Yes
Ambient Temp Range -40°C ~ 125°C (TJ)
Quality Grade Level -
Certification Qualification -
Attachment Mounting Style Surface Mount
Component Housing Style 159-BBGA Power Module
Vendor Package Type 159-BGA Power Block (15.5x9.25)

Description

Yields output current measured at 30A, 15A. Engineered for a 170kHz ~ 460kHz switching frequency ideal for high-speed electronic uses. Engineered with Step-Down features for versatile component usage. The input voltage established at 3.14V for reliable performance. Mounting configuration Surface Mount for structural stability. Overall outputs 1 or 2 for device connections. Temperature range -40°C ~ 125°C (TJ) for environmental conditions impacting thermal efficiency. Preferences Positive for establishing system output configurations. Type Adjustable for ensuring compatibility with output systems. Voltage 3.3V for optimal output electric potential. Type of housing Tape & Reel (TR) for safeguarding or transporting components. Style of the enclosure/case 159-BBGA Power Module that offers mechanical and thermal protection. Type of package 159-BGA Power Block (15.5x9.25) that preserves the integrity of the device. Product status Obsolete concerning availability and lifecycle. Classification series for the product or component iPOWIR™. Supplier package type 159-BGA Power Block (15.5x9.25) for component selection. The ability for synchronous rectification Yes to improve energy efficiency. Layout design Buck for electrical systems or configurations. Maximum input voltage 5.5V for safeguarding. Minimum input voltage 3.14V for operation. The maximum output voltage 3.3V for devices. The lowest or steady output voltage 0.8V for circuits.